ITC-11 Electrical Distribution Network Installation Guide: Rush

ITC-11

1. RUSH

1.1. Definition

Part of the installation of the distribution network, which feeds the box or general protective boxes or functional equivalent unit (hereinafter GPC).

1.2. Types of Rush

Based on its design, system installation and network features, the rush may be:

TYPESYSTEM INSTALLATION
AirPosada on facade
Stretched over pole
UndergroundWith input and output
Shunt
MixedAero-Ground
1.2.1. Air Rush on Facade

Prior to its implementation, if possible, should be a prior study of the facades so that

Read More

Spatial Structures, Wood-Based Panels, and Concrete in Construction

Components of Spatial Structures (Steel Mesh)

Steel Profiles

Steel profiles (hot or cold-rolled) may have different sections:

  • Open profiles: I, M, U, L
  • Closed profiles: Circular, square, and others

Knots (Connections)

The connections are key to achieving a stable structure. Several methods exist:

  • Welding: Requires extensive non-destructive testing to ensure proper execution.
  • Screws: Transmit applied forces, supporting shear or reactions in the section. The usual practice is to place 2 screws per connection.
Read More

Hard Drive Technology: Understanding Storage, Formatting, and Error Types

Magnetic Disks, Recording Formats

1. What is a CHS address?

The CHS address represents the coordinates of a specific area on a hard drive, determined by the cylinder, head, and sector.

3. At what time can we decompose the total access time? Indicate typical values of current hard disks.

The total access time can be decomposed into:

  • Search time: The time spent moving the head to the required track. The average value typically does not exceed 10 ms.
  • Latency time: Once the head is on the track, this is the
Read More

General Protection Boxes and Protection and Measurement Boxes in Electrical Installations

General Protection Boxes

1.2. Location and Installation

  • Installed on exterior building facades with free and permanent access.
  • Location determined by agreement between property owner and supplier.
  • May use low voltage fuse box or distribution transformer as general protective box if building houses these components.
  • For overhead connections, installed on surface at height of 3-4m.
  • For underground connections, installed in wall niche with metal door and degree of protection IK 10.
  • Bottom of door at least
Read More

Rush: Definition, Types, Installation, and Characteristics

1. Rush: Definition

Part of the installation of the distribution network, which feeds the box or general protective boxes or functional equivalent unit (hereinafter GPC).

1.2. Types of Rushes

Based on its design, system installation, and network features, the rush may be:

TYPESYSTEM INSTALLATION
AirPosada on facade
Stretched over pole
UndergroundWith input and output
Shunt
MixedAero-Ground

1.2.1. Inn Air Assault on Facade

Prior to its implementation, if possible, should be a prior study of the facades so that

Read More

Introduction to Naval Terminology and Maneuvering

1. Naval Technology

1.1. Dimensions

Maximum Length: Length of the boat, measured parallel to the design waterline between two planes perpendicular to the centerline, one forward and one aft, excluding non-structural elements of the hull.

Beam: Width of the boat, measured at the widest point of the hull, including fixed structures.

Depth: Can have three possible meanings:

  1. Maximum vertical dimension measured from the top of the keel to the main deck.
  2. Each of the pillars supporting the roofs.
  3. Mast used to
Read More